PhenX - refractive error - child protocol 111402

General Details:

Name:
PhenX - refractive error - child protocol 111402
Steward:
PhenX
Definition:
Refractive error in children is measured using cycloplegic autorefraction with the Retinomax. Eyes undergo cycloplegia after pupillary dilating eyedrops and eight readings of refractive error of each eye are taken with the Retinomax in the Refractions and Keratometry mode. In instances where cycloplegic autorefraction cannot be obtained on an eye or when it is of poor quality (Retinomax confidence rating <= 7), cycloplegic retinoscopy is performed to obtain a measure of refractive error. This protocol uses Retinomax to measure refractive error in children. Other instruments can be used to measure refractive error. If other instruments are used, the reproducibility of the measurements should be comparable to those acquired with this protocol. In addition, when other instruments are used to collect these measurements, the manufacturer and model of equipment should be recorded. These other devices may require some different steps than are described in this protocol. Investigators should follow the equipment manufacturer's instructions to ensure quality control.
Registration Status:
Qualified

Designations:

Designation:
PhenX - refractive error - child protocol 111402
Tags:
Long Common Name
Designation:
Refractive error child proto
Tags:
Short Name

Designations:

Definition:
Refractive error in children is measured using cycloplegic autorefraction with the Retinomax. Eyes undergo cycloplegia after pupillary dilating eyedrops and eight readings of refractive error of each eye are taken with the Retinomax in the Refractions and Keratometry mode. In instances where cycloplegic autorefraction cannot be obtained on an eye or when it is of poor quality (Retinomax confidence rating <= 7), cycloplegic retinoscopy is performed to obtain a measure of refractive error. This protocol uses Retinomax to measure refractive error in children. Other instruments can be used to measure refractive error. If other instruments are used, the reproducibility of the measurements should be comparable to those acquired with this protocol. In addition, when other instruments are used to collect these measurements, the manufacturer and model of equipment should be recorded. These other devices may require some different steps than are described in this protocol. Investigators should follow the equipment manufacturer's instructions to ensure quality control.
Tags:
Source: Regenstrief LOINC

Properties:

Key:
Related Names
Value:
PanPanelPANEL.PHENX
PanlPnlPoint in time
RandomRefractive error child proto
Key:
Related Codes
Value:
Code SystemCodeCode TextCode Version
https://www.phenxtoolkit.org111402refractive_error___children
Key:
Fully-Specified Name
Value:
ComponentPropertyTimeSystemScaleMethod
PhenX - refractive error - child protocol 111402-Pt^Patient-PhenX
Key:
Basic Attributes
Value:
ClassTypeFirst ReleasedLast UpdatedChange ReasonPanel Type
PANEL.PHENXClinicalVersion 2.36Version 2.66Updated the PhenX ID from "PhenX." to "PX" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.Panel

Identifiers:

Source:
NLM
Id:
X1Gn3zTnie
Version:
1.0
Source:
PhenX
Id:
111402
Version:
Source:
LOINC
Id:
62707-5
Version:
2.69